1

GT-M-E

Multipurpose Digital Contact Sensor

GT2 series, models, model list, Amplifier, Cable, Controller/Head, Main unit, Other option, Software, KEYENCE, Canada tcm:47-745021-64 To use all available functions on this website, JavaScript must be enabled in your browser. GT2-H12K, Sensor Head, High-precision Type, GT2 series, KEYENCE, Singapore tcm:39-493808-64 To use all available functions on this website, JavaScript must be enabled in your browser.

GT-70A

Series Instruction Manual

Safety Precautions

General cautions

• At startup and during operation, be sure to monitor the function

performance of the GT-70A Series.

• Do not modify the GT-70A Series or use it in any way other than

described in the specifications. The function performance of
products used or modified in this way cannot be guaranteed.

• When the GT-70A Series is used in combination with other

instruments, function performance may be degraded, depending on
operating conditions and the surrounding environment. Use the GT-
70A Series after fully studying the effect of combined use with other
instruments.

• Do not use the GT-70A Series for the purpose of protecting the

human body.

• Do not expose the GT-70A Series and peripheral devices to sudden

temperature change. This may cause condensation, damaging the
equipment.

● Environmental conditions

To use the GT-70A Series properly and safely, do not install the GT-70A
Series in the following locations. Use of this equipment in an improper
environment may cause equipment failure.

Locations with high humidity, a large amount of dust, or poor ventilation Ma 3spa overhaul manual.

Locations where the temperature rises excessively due to direct
sunlight, etc.

Locations near corrosive or flammable gas

Keyence gt2 series user manual 2017

Locations where the GT-70A Series is directly subjected to
vibration or impact

Locations where water, oil or chemicals may come into contact with
the GT-70A Series

Locations where static electricity may easily occur

● Noise countermeasures

Installation near the noise source such as a power source and a
power cable may cause malfunction or failure of the equipment.
Adopt appropriate countermeasures against noise by using a noise
filter or wiring cables in separate ducts, attaching insulation to the
amplifier or the sensor head, etc.

● Effects of ambient temperature

Change in ambient temperature may cause detection errors. Keep
ambient temperature at a constant level.
It will take about 40 minutes for the internal temperature distribution
of the equipment to completely adjust when the ambient
temperature has changed by 10°C.

● Warming up

Wait about 30 minutes after the power is turned ON before beginning
operation. Immediately after the power is turned ON, the circuit
becomes unstable, possibly causing the indicated value to slightly
fluctuate.

Vrinda font for mac. ● Handling of the sensor head

The GT-70A Series and peripheral devices are precision machines.
Do not drop, or cause any other impact to these devices.

Do not apply weight greater than what is listed below to the spindle part.
Do not apply torque in the rotation direction. Otherwise the spindle may
break.

Although the sensor head has a waterproof structure, avoid using in
water or in the place where liquid such as water and oil may come into
contact with the sensor head.

● Extending cable between amplifier and sensor head

Do not cut or extend the cable between the amplifier and the sensor
head. This may change the characteristics, causing the
specifications not to be satisfied.

● Power supply

Noise superimposed on the power supply may cause malfunction.
Be sure to use the DC stabilized power supply provided with an
insulation transformer.

In the case of a commercially available switching regulator, be
sure to ground the frame ground terminal or the ground terminal.

● Effects of vibration

Vibrating the detection target may cause fluctuation in the indicated
value. In this case, extend the response time. This ensures more
accurate detection values.

● Effects of magnetic fields

Contact by an external magnetic field to the sensor head will
influence the output. Avoid installing the GT-70A Series near motors
or other equipment and devices that generate strong magnetic
fields.

● About dust protective boot

An optional dust protective boot is available (GT-H10: OP-78041, GT-
H22: OP-78042) for when the included dust protective boot has been
cracked or damaged. Please note that we cannot guarantee the
protection rating IP67 when the optional part is used. If you need a
guarantee for the protection rating IP67, replace the sensor head
itself.

WARNING Dropzone 3 3 6 7.

If the following conditions are encountered,
immediately turn OFF the power. Continuing to use
the GT-70A Series under these abnormal conditions
may cause equipment failure.
• When water or foreign matter enters the controller
• When the GT-70A Series is dropped or the housing

is damaged

• When the GT-70A Series produces smoke or an

abnormal smell

Keyence Gt2 71p Manual

WARNING

• Do not use the GT-70A Series with a voltage other

than specified voltage, as this may cause fire,
electric shock or equipment failure.

• Do not disassemble or modify the GT-70A Series.

This may cause fire or electric shock.

CAUTION

• Be sure to turn OFF the power of the GT-70A Series and

any connected devices before connecting or
disconnecting the cables. Otherwise, there may be a risk
of damage.

• Do not turn OFF the power while setting parameters.

Otherwise, the settings may be partially or completely lost.

30 N

100 N

1 N

96M1825

Advertising
Table of contents
  • Safety Precautions
  • Package Contents
  • Mounting the Amplifier and Wiring
  • Connecting and Mounting the Sensor Head
  • Amplifier display
  • Zero-Point Correction
  • Setup of Range Limit Values
  • Tips for Convenient Functions
  • Setting Mode Display
  • Specifications
  • Circuit diagram
Popular Brands
Popular manuals
Loading.

96M12124

Adapter for GP-M Series Precautionary Points When Installing

Symbols

NOTICE It indicates a situation which, if not avoided, could result in product damage as well as property damage.

Installation method

NOTICE Always use the O-Ring included with the sensor unit.

1 Fit the O-Ring included with the sensor unit to the groove in the adapter as in the diagram on the right.

When using the G1/4 Female convertible adapter (OP-87283), attach the O-Ring

NOTICE included with the OP-87283 to the groove of the piping connection part (the G1/4 screw portion) of the adapter.

2 Connecting the sensor unit/adapter/piping

After installation, the body may be rotated horizontally to 330°. When rotating, hold the clasp in place with something such as a wrench.

GP-M001/M010/M025

GP-M100/M250/M400

Included with

Included with

the sensor unit

the sensor unit

(OP-87287)

(OP-87288)

Adapter

Adapter

Sensor main unit

O-Ring

Adapter

(When using the OP-87281)

Piping

Throttle (OP-87311/87312)

For adapters other than the cheese adapter (OP-87286/87644), a separately sold throttle (Minimum width ø0.5 mm) to lessen vibration and surge pressure can be installed. Especially for the GP-M100/M250/M400, installation of the throttle is recommended.

OP-87311(Corresponding adapter: OP-87280/87281/87282/87284/87285) is installed to the sensor unit installation part (G3/4 female screw).

OP-87312Corresponding adapter: OP-87283) is installed to the piping installation part (G1/4 female screw). Install each with a flathead screwdriver. (Recommended tightening torque: 1.2 N•m)

Common precautionary points

The recommended tightening torque when installing an adapter to the Sensor unit is 20 N•m.

Keyence Gt2 Series User Manual 2017

It is recommended to apply grease to the G3/4 male screw part of the sensor main unit to prevent scorching.

Keyence Gt2 Series Manual

If the O-Ring is damaged it is possible that liquid will leak, therefore please purchase the following optional attachment. O-Ring for the GP-M001/M010/M025: OP-87287O-Ring set for the GP-M100/M250/M400: OP-87288

G1/4 female adapter (OP-87283) piping side O-Ring: OP-87310

When replacing the O-Ring, ensure that there is no debris on the surface to come in contact with the O-Ring.





broken image